Operation Theater Direct Expansion Air Handling Unit
1.Forward fan/backward fan/plug fan/EC fan
2.SS 304 drain pan
3.30mm/50mm PU insulation with excellent thermal break performance
3.Aluminum filter, panel filter ,bag filter
4. Complied with national medical industrial standard
5. Clean and multiple sterilization
6. Flexible combination , easy maintenance
7. Silent design, quiet operation
8. Reliable sealing, better insulation
9. Fresh air, protect your health
Clean Operation Room Air Handling Unit-Direct expansion mixing air

Model Cooling only PWYJ-020A PWYJ-050A PWYJ-065A PWYJ-080A PWYJ-100A PWYJ-120A PWYJ-140A PWYJ-170A PWYJ-200A PWYJ-230A
Rated air flow m³/h 2000 5000 6500 8000 10000 12000 14000 17000 20000 23000
ESP Pa 700 700 700 700 700 700 700 700 700 700
Motor power KW 1.5 2.2 4 4 5.5 7.5 7.5 11 11 11
Cooling KW 13.3 27 30.8 40.6 54.1 61.6 81.4 95.2 108.2 123.2
Heating coil(2 rows) KW 20.1 42.6 56.3 60.4 74.4 107 137.9 158.8 182.6 219.4
Steam coil(2 rows) KW 28.3 68.4 90.4 125 144.9 167.8 203 236.2 278.1 323.7
Auxiliary electric heater Type PTC electric heater
Power
KW
3 12 13.5 18 24 27 31.5 36 45 54
Humidifier Type Electrode humidifier
Capacity
Kg/h
4 9 15 15 15 22 22 22 30 30
Power
KW
3 6.8 11.3 11.3 11.3 16.5 16.5 16.5 22.5 22.5
Primary filter Efficiency G4
Medium filter Efficiency F8
Power supply 3PH-380V/50Hz
Dimensions L mm 3300 3650 3750 3750 3800 3900 3950 4200 4200 4500
W mm 900 1000 1200 1300 1500 1700 1600 1800 2000 2100
H mm 700 1080 1180 1180 1280 1300 1500 1700 1700 1850
Condensing unit 5 10 12 15 20 25 30 36 40 48
Pipe connection Horn valve Welding
 
Remark:
1. Cooling capacity is measured at nominal air volume, indoor dry and wet bulb temperature of 24° C 17° C and outdoor dry and wet bulb temperature of35。C /28"C;
2. The heat is measured under the conditions of nominal air volume, dry bulb temperature of 24°C, wet bulb temperature of 7C, inlet and outlet temperature of high temperature hot water of 90°C/60°C, and steam pressure of 70kPa in the return air chamber;
3. The unit is standard equipped with hot water coil, and can also be heated by electric or steam according to customer requirements; .
4. The unit is standard equipped with electrode humidification, or dry steam or other methods according to customer requirements;
5. The amount of heat and humidification is determined according to the user's local climate parameters.
 
 
 
Clean Operation Room Air Handling Unit-Direct expansion total fresh air 

Model Cooling only PWYJ-20AX PWYJ-50AX PWYJ-65AX PWYJ-80AX PWYJ-100AX PWYJ-120AX PWYJ-140AX PWYJ-170AX PWYJ-200AX PWYJ-230AX
Rated air flow m³/h 2000 5000 6500 8000 10000 12000 14000 17000 20000 23000
ESP Pa 500 500 500 500 500 500 500 500 500 500
Motor power KW 2.2 4 4 5.5 7.5 7.5 11 11 15 15
Cooling KW 20 61.6 75 95.2 115.6 132.2 162.8 184.6 244.2 276.9
Heating coil(2 rows) KW 26.2 56.8 75.2 98.3 121.4 142.9 184.3 215 249.1 291.4
Steam coil(2 rows) KW 33.3 77.1 101.7 130 163.2 188.9 228.6 266 313.2 380.2
Dehumidification compressor HP*Qty -- 3*1 4*1 5*1 6*1 4*2 4*2 5*2 6*2 15*1
Primary filter Efficiency G4
Medium filter Efficiency F8
HEPA filter Efficiency H10
Power supply 3PH-380V/50Hz
Dimensions L mm 3700 4050 4150 4150 4300 4400 4400 4400 4700 4900
W mm 900 1000 1200 1300 1500 1700 1600 1800 2000 2100
H mm 700 1080 1180 1180 1280 1300 1500 1700 1700 1850
Condensing unit 8 24 15*2 18*2 22*2 26*2 30*2 36*2 30*3 36*3
Pipe connection Horn valve Welding
 
Remark:
1. Cooling capacity is measured at nominal air volume and fresh air dry and wet bulb temperature of 34°C/28 °C;
2. The heat is measured under the condition of nominal air volume, fresh air dry bulb temperature of 7° C, high temperature hot water inlet and outlet temperature of 90° C /60° C, and steam pressure of 70kPa;
3. The unit is standard equipped with hot water coil, and can also be heated by electric or steam according to customer requirements; .
inquiry
Leave your phone number in your mailbox, we will call you within 24 hours
  • Submit