Operation Theater Chilled Water Air Handling Unit
Air flow :2,000m3/h-23,000m3/h
1.Forward fan/backward fan/plug fan/EC fan
2.SS 304 drain pan
3.30mm/50mm PU insulation with excellent thermal break performance
3.Aluminum filter, panel filter ,bag filter
4. Complied with national medical industrial standard
5. Clean and multiple sterilization
6. Flexible combination , easy maintenance
7. Silent design, quiet operation
8. Reliable sealing, better insulation
9. Fresh air, protect your health
 

Clean Operation Room Air Handling Unit-Chilled water mixing air
 
Model Cooling only PWYJ-20 PWYJ-50 PWYJ-65 PWYJ-80 PWYJ-100 PWYJ-120 PWYJ-140 PWYJ-170 PWYJ-200 PWYJ-230
Rated air flow m³/h 2000 5000 6500 8000 10000 12000 14000 17000 20000 23000
ESP Pa 700 700 700 700 700 700 700 700 700 700
Motor power KW 1.5 2.2 4 4 5.5 7.5 7.5 11 11 11
Chilled water coil Cooling
(KW)
4 Rows 10.7 23.8 30.9 38.9 49.4 58.2 73.7 81.6 96 112.7
6 Rows 12.5 30.1 39.1 46.7 57.7 73.7 83.6 103.4 121.6 142.7
8 Rows 14 32.3 42 53.4 66.7 79.1 96.5 110.9 130.5 153.1
Heating coil(ST T) Heating
(KW)
2 Rows 11.4 27.1 35.2 39.8 56.9 66.3 78.9 92.9 109.3 128.2
4 Rows 17 37.7 49 61.7 78.4 92.4 117 129.6 152.4 178.8
6 Rows 19.3 46.3 60.2 71.8 88.8 113.4 132.8 159 187.1 219.5
8 Rows 20.6 47.5 61.7 78.5 98.1 116.3 141.9 163.1 191.9 225.2
Heating coil(High T) Heating
(KW))
1 Row 11.2 24.5 32.6 41.7 51.5 61.9 80.2 90.3 100.8 115.1
2 Rows 20.1 42.6 56.3 60.4 74.6 107 137.9 158.8 182.6 219.4
Steam coil Heating
(KW)
1 Row 16.5 39.6 52.4 71.6 84.8 97.4 118.9 137 161.3 192.1
2 Rows 28.3 68.4 90.4 125 144.9 167.8 203 236.2 278.1 323.7
Auxiliary electric heate Type PTC electric heater
Power
KW
3 12 13.5 18 24 27 31.5 36 45 54
Humidifier Type Electrode humidifier
Capacity
Kg/h
4 9 15 15 15 22 22 22 30 30
Power
KW
3 6.8 11.3 11.3 11.3 16.5 16.5 16.5 22.5 22.5
Primary filter Efficieny G4
Medium filter Efficieny F8
Dimensions L mm 3300 3650 3750 3750 3800 3900 3950 4200 4200 4500
W mm 900 1000 1200 1300 1500 1700 1600 1800 2000 2100
 H mm 700 1080 1180 1180 1280 1300 1500 1700 1700 1850


Remark:
1. Cooling capacity is measured under the condition of nominal air flow, indoor dry and wet bulb temperature of24°C/17° C, outdoor dry and wet bulb temperature of 35° C /28。C, and frozen water inlet and outlet temperature of 7/12° C;
2. The heat is measured under the condition of nominal air volume, dry bulb temperature of 24°C, wet bulb temperature of 7°C, inlet and outlet temperature of low temperature hot water of 60/50° C, inlet and outlet temperature of high temperature hot water of 90°C /60° C, steam pressure of 70kPa;
3. The unit is standard equipped with hot water coil, and can also be heated by electric or steam according to customer requirements;
4. The unit is standard equipped with electrode humidification, or dry steam or other methods according to customer requirements;
5. The amount of heat and humidification is determined according to the user's local climate parameters.