Operation Theater Chilled Water Air Handling Unit
Air flow :2,000m3/h-23,000m3/h
1.Forward fan/backward fan/plug fan/EC fan
2.SS 304 drain pan
3.30mm/50mm PU insulation with excellent thermal break performance
3.Aluminum filter, panel filter ,bag filter
4. Complied with national medical industrial standard
5. Clean and multiple sterilization
6. Flexible combination , easy maintenance
7. Silent design, quiet operation
8. Reliable sealing, better insulation
9. Fresh air, protect your health
2.SS 304 drain pan
3.30mm/50mm PU insulation with excellent thermal break performance
3.Aluminum filter, panel filter ,bag filter
4. Complied with national medical industrial standard
5. Clean and multiple sterilization
6. Flexible combination , easy maintenance
7. Silent design, quiet operation
8. Reliable sealing, better insulation
9. Fresh air, protect your health
Clean Operation Room Air Handling Unit-Chilled water mixing air
Model | Cooling only | PWYJ-20 | PWYJ-50 | PWYJ-65 | PWYJ-80 | PWYJ-100 | PWYJ-120 | PWYJ-140 | PWYJ-170 | PWYJ-200 | PWYJ-230 | |
Rated air flow | m³/h | 2000 | 5000 | 6500 | 8000 | 10000 | 12000 | 14000 | 17000 | 20000 | 23000 | |
ESP | Pa | 700 | 700 | 700 | 700 | 700 | 700 | 700 | 700 | 700 | 700 | |
Motor power | KW | 1.5 | 2.2 | 4 | 4 | 5.5 | 7.5 | 7.5 | 11 | 11 | 11 | |
Chilled water coil |
Cooling (KW) |
4 Rows | 10.7 | 23.8 | 30.9 | 38.9 | 49.4 | 58.2 | 73.7 | 81.6 | 96 | 112.7 |
6 Rows | 12.5 | 30.1 | 39.1 | 46.7 | 57.7 | 73.7 | 83.6 | 103.4 | 121.6 | 142.7 | ||
8 Rows | 14 | 32.3 | 42 | 53.4 | 66.7 | 79.1 | 96.5 | 110.9 | 130.5 | 153.1 | ||
Heating coil(ST T) |
Heating (KW) |
2 Rows | 11.4 | 27.1 | 35.2 | 39.8 | 56.9 | 66.3 | 78.9 | 92.9 | 109.3 | 128.2 |
4 Rows | 17 | 37.7 | 49 | 61.7 | 78.4 | 92.4 | 117 | 129.6 | 152.4 | 178.8 | ||
6 Rows | 19.3 | 46.3 | 60.2 | 71.8 | 88.8 | 113.4 | 132.8 | 159 | 187.1 | 219.5 | ||
8 Rows | 20.6 | 47.5 | 61.7 | 78.5 | 98.1 | 116.3 | 141.9 | 163.1 | 191.9 | 225.2 | ||
Heating coil(High T) |
Heating (KW)) |
1 Row | 11.2 | 24.5 | 32.6 | 41.7 | 51.5 | 61.9 | 80.2 | 90.3 | 100.8 | 115.1 |
2 Rows | 20.1 | 42.6 | 56.3 | 60.4 | 74.6 | 107 | 137.9 | 158.8 | 182.6 | 219.4 | ||
Steam coil |
Heating (KW) |
1 Row | 16.5 | 39.6 | 52.4 | 71.6 | 84.8 | 97.4 | 118.9 | 137 | 161.3 | 192.1 |
2 Rows | 28.3 | 68.4 | 90.4 | 125 | 144.9 | 167.8 | 203 | 236.2 | 278.1 | 323.7 | ||
Auxiliary electric heate | Type | PTC electric heater | ||||||||||
Power KW |
3 | 12 | 13.5 | 18 | 24 | 27 | 31.5 | 36 | 45 | 54 | ||
Humidifier | Type | Electrode humidifier | ||||||||||
Capacity Kg/h |
4 | 9 | 15 | 15 | 15 | 22 | 22 | 22 | 30 | 30 | ||
Power KW |
3 | 6.8 | 11.3 | 11.3 | 11.3 | 16.5 | 16.5 | 16.5 | 22.5 | 22.5 | ||
Primary filter | Efficieny | G4 | ||||||||||
Medium filter | Efficieny | F8 | ||||||||||
Dimensions | L mm | 3300 | 3650 | 3750 | 3750 | 3800 | 3900 | 3950 | 4200 | 4200 | 4500 | |
W mm | 900 | 1000 | 1200 | 1300 | 1500 | 1700 | 1600 | 1800 | 2000 | 2100 | ||
H mm | 700 | 1080 | 1180 | 1180 | 1280 | 1300 | 1500 | 1700 | 1700 | 1850 |
Remark:
1. Cooling capacity is measured under the condition of nominal air flow, indoor dry and wet bulb temperature of24°C/17° C, outdoor dry and wet bulb temperature of 35° C /28。C, and frozen water inlet and outlet temperature of 7/12° C;
2. The heat is measured under the condition of nominal air volume, dry bulb temperature of 24°C, wet bulb temperature of 7°C, inlet and outlet temperature of low temperature hot water of 60/50° C, inlet and outlet temperature of high temperature hot water of 90°C /60° C, steam pressure of 70kPa;
3. The unit is standard equipped with hot water coil, and can also be heated by electric or steam according to customer requirements;
4. The unit is standard equipped with electrode humidification, or dry steam or other methods according to customer requirements;
5. The amount of heat and humidification is determined according to the user's local climate parameters.
inquiry
Leave your phone number in your mailbox, we will call you within 24 hours