Total Fresh Air Dual-Cooling Source Dehumidification Modular AHU
Air flow 2,000m3/h-23,000m3/h
1.Forward fan/backward fan/plug fan/EC fan
2.SS 304 drain pan
3.30mm/50mm PU insulation with excellent thermal break performance
3.Aluminum filter, panel filter ,bag filter ,HEPA filter
4. Double cooling source for further dehumidification
5. Coil heat exchanger, better heat exchange efficiency
6. Clean and multiple sterilization
7. Flexible combination , easy maintenance
8. Silent design, quiet operation
9. Reliable sealing, better insulation
10. Fresh air, protect your health

Total Fresh Air Dual-Cooling Source Dehumidification Modular AHU
 

Model Cooling only PWYJ-20T PWYJ-50T PWYJ-65T PWYJ-80T PWYJ-100T PWYJ-120T PWYJ-140T PWYJ-170T PWYJ-200T PWYJ-230T
Rated air flow m³/h 2000 5000 6500 8000 10000 12000 14000 17000 20000 23000
ESP Pa 500 500 500 500 500 500 500 500 500 500
Motor power KW 2.2 4 4 5.5 7.5 7.5 11 11 15 15
Chilled water coil Cooling (KW) 4 Rows 25.6 64.2 83.2 102.2 130 152.5 182.1 220.8 269.3 306.2
6 Rows 32.8 83.2 106.5 129.5 169.3 187.2 223 270.3 326.7 374.8
8 Rows 36.8 93.5 122.2 150.8 186.2 220 257.8 311.6 365.8 424.2
Heating coil(ST T) Heating
(KW)
2 Rows 15.5 38.9 50.4 61.9 85 103 110.3 133.7 163.1 185.5
4 Rows 25.9 64.8 84 103.2 132 156 184.8 224.1 273.3 310.8
6 Rows 28.7 72.8 93.2 113.6 153 189 195.1 236.5 285.8 327.9
8 Rows 32 81.3 106.2 131.1 165 203 224.1 270.8 317.9 368.7
Heating coil(High T) Heating
(KW)
1 Row 15.4 32.7 43.9 57.8 71.4 83.4 108.1 122.8 138.9 158.6
2 Rows 26.2 56.8 75.2 98.3 121.4 142.9 184.3 215 249.1 291.4
Steam coil Heating
(KW)
1 Row 19.3 44.1 58.5 75.3 94.5 108.7 132.5 152.8 179.9 218.4
2 Rows 33.3 77.1 101.7 130 163.2 188.9 228.6 266 313.2 380.2
Dehumidification compressor HP*Qty -- 3*1 4*1 5*1 6*1 4*2 4*2 5*2 6*2 15*1
Primary filter Efficieny G4
Medium filter Efficieny F8
HEPA filter Efficieny H10
Dimensions L mm 3700 4050 4150 4150 3800 4400 4450 4700 4700 4900
W mm 900 1000 1200 1300 1500 1700 1600 1800 2000 2100
 H mm 700 1080 1180 1180 1280 1300 1500 1700 1700 1850
Remark:
1. Cooling capacity is measured under the condition of nominal air volume, fresh air dry and wet bulb temperature of 34° C /28。C, and chilled water inlet and outlet temperature of 7/12°C;;
2. The heat production is measured under the condition of nominal air volume, fresh air dry bulb temperature of 7°C, low temperature hot water inlet and outlet temperature of 60/50*C, high temperature hot water inlet and outlet temperature of 90°C/60C, steam pressure of 70kPa;
3. The standard configuration of the unit is hot water coil. If you need to use other heating, please indicate when ordering.
inquiry
Leave your phone number in your mailbox, we will call you within 24 hours
  • Submit