Commercial EVI Heat Pump Chiller

This series can provide heating in winter and cooling in summer for family and large buildings by connecting with fan coil units. Adopt environmental-friendly refrigerant R410a. working good at -25℃ above area.
 
Features & Benefits

1.Cooling in summer;heating in winter at -25degrees.

2.Strong Cabinet; Standard unit fabrication consists of heavy galvanized sheet metal cabinet construction that provides maximum strength.

3.American Copeland scroll compressor guarantees stable and high efficient working.

4.High efficient tube in shell heat exchanger.
5.Intelligent control and Automatic Data Backup (with self-diagnosis function, auto-defrosting function, complete protection function) to ensure reliable operation.

6.Reliable Design and Strict Quality Control;All products are tested and run at the factory to assure proper operation of all components and safety switch.


Commercial EVI Heat Pump Chiller
Model No.PW150-DKFLRSPW250-DKFLRSPW300-DKFLRSPW500-DKFLRSPW600-DKFLRSPW1000-DKFLRS
Rated HeatingHeating CapacitykW427288144176288
Power InputkW12.721.125.242.250.484.4
COPW/W3.31 3.41 3.49 3.41 3.49 3.41 
Nominal Heating (-12)Heating CapacitykW29.0 50.3 60.5 100.8 121.0 201.6
Power InputkW12.6 21.6 26.1 43.6 52.4 87.2
COPW/W2.30 2.33 2.32 2.31 2.31 2.31 
IPLV (H)W/W2.61 2.68 2.67 2.66 2.65 2.66
Heating (-20)Heating CapacitykW24.7 42.8 51.4 85.7 102.9 171.3
Power InputkW13.4 22.9 27.5 46.1 55.2 85.5
COPW/W1.84 1.87 1.87 1.86 1.86 2.00 
Heating(-25)Heating CapacitykW20.3 35.2 42.4 70.6 84.7 141.2
Power InputkW13.5 23.1 27.8 46.6 55.6 86
COPW/W1.50 1.52 1.52 1.51 1.52 1.64 
Rated CoolingCooling CapacitykW36.26475128150256
Power InputkW13.322.927.345.854.695.5
EERW/W2.72 2.79 2.75 2.79 2.75 2.68 
IPLV (C)W/W2.82 29.30 2.91 2.95 2.97 2.95
Rated CurrentA26.6 45.8 54.6 91.6 109.2 183.2
Max CurrentA39.9 68.7 81.9 137.4 163.8 274.8
CompressorCopeland
Heat ExchangerTube-in-Shell
Power Supply3PH/380V/50Hz
Anti-electric Shock Rate
IP Grade (Level of Protection)IPX4
Air BlowingVertical Blowing
RefrigerantR410A/8000gR410A/8000g×2R410A/7500g×2R410A/11500g×2R410A/8500g×4R410A/12000g×4
Working Ambient TempEVI Type-25-43
NoisedB(A)626265696972
Water Pressure DropkPa464646555555
Water CirculationM3/h6.23 11.01 12.90 22.02 25.80 44.03 
Diameter of PipeDN40(male thread)DN65(flange)DN65(flange)DN65(flange)DN65(flange)DN100(flange)
Net Weightkg400760880105014502400
Product SizeLengthmmU-shape 1020U-shape 2000U-shape 2000V-shape 2400U-shape 2400V-shape 3000
Widthmm98010001000110013002200
Heightmm187019001900220023502270
Rated Cooling Working Condition: Dry bulb temperature 35, Wet bulb temperature 24, Inlet water temperature 12, Outlet water temperature 7.
Rated Heating Working Condition: Dry bulb temperature 7, Wet bulb temperature 6, Inlet water temperature 40, Outlet water temperature 45.
Nominal Heating Working Condition: Dry bulb temperature -12, Wet bulb temperature -14, Outlet water temperature 41.
Heating Working Condition (-20): Dry bulb temperature -20, Outlet water temperature 41.
Heating Working Condition (-25): Dry bulb temperature -25, Outlet water temperature 41.
inquiry
Leave your phone number in your mailbox, we will call you within 24 hours